Acoustic Measurements - As Tested by Western Electro Acoustic Lab, Santa Monica, CA

Laboratory Measurements

Freq (Hz)

250
500
1000
2000
4000

AC* (0.6)

.21
.64
.88
.72
.58

STL** (25)

23
23
24
36
36
* Absorption Coefficient Per ASTMC 423-90a
** Sound Transmission Loss Per ASTME-413 procedure E90-90

Field Measurements:

-Transmission Loss

12 ft High Wall

Albany Airport, NY

Broadband Aircraft Engine Noise - 16 dBA

8 ft High Wall

Culver City, Ca

Electrical Transformer Noise 120 & 240 Hz - 13dBA

20 ft High Wall

Chula Vista Ampitheater, CA

Broadband Noise Transmission Loss - 26 dba

-Echo reduction

20 ft High Wall

Chula Vista, CA @ 100Hz 50 % Concrete & 50% QUILITE

-10dBA

20 ft High Wall

Chula Vista, CA Broadband Echo 100% Concrete

See Fig. A

20 ft High Wall

Chula Vista, CA Broadband Echo 50% Concrete & 50% QUILITE

See Fig. B
 
Figure 1
Echo From 100% Concrete Wall Surface Area
Figure 2
Echo From 50% Concrete & 50% QUILITE Wall Surface Area
Figure 3
Combination reflection graph of broad band sound between a concrete wall and a combination QUILITE wall

Figure 2 shows that the nominal echo from the combination wall surface has approximately half the intensity of the 100% concrete wall (Figure A). This indicates the net reflection efficiency of QUILITE is significantly lower than implied by the Lab measured absorbtion coefficient